The hot channel enclosure is composed oflightweight aluminum profiles and insulated polycarbonate panels, which enhance heat dissipation and save energy in high-density demand computer rooms. Better than cold aisle heat dissipation and more mo dular assembly structure, widely used in large capacity data centers.
① The structural support adopts multi segment aluminum alloy profiles pre spliced, and the aluminum alloy profiles are prefabricated into several modules. The modular assembly mode is adopted on site, and there is no form ofwelding on site.
② The sealed structural components ofthe channel are independent supports and do not require a rack as a support.
③ Reserve space on the channelframe for installing cameras, lighting fixtures, differential pressure sensors, smoke and temperature sensors, etc.
① The suspended closed hot aisle consists ofhan ging components, seismic brackets, aluminum alloyframe components, aisle doors, adapter plates, brushes, and their sealing accessories.
② The hanging components are made of one-time rolled C-shaped steel or U-shaped steel spliced together, and the top is fixed to the floor with adjustable height connecting plates.
③ Three sided inclined seismic supports are installed at both ends ofthe hanging channel to ensure the overall strength of the hanging system in both vertical and horizontal directions.
④ The frame is made of 6063-T5 aluminum alloy (natural anodized), and the cross-section meets national standards. The internal baffle ofthe frame adopts double-layer hollowfireproof sunlight board, with a middle air layer and a heattransfer coefficient of<4.5W/(m2 x K). The channel door adopts a double opening sliding door Japanese shaped structure to increase strength and stability. The left and right doors are closed with magnetic attraction to increase the tightness ofhe channel.
① Arrange the cabinets in a back-to-back manner, creating a completely enclosed area from the top ofthe cabinet's rear door to the ceiling, with a hot aisle area that allows the heat source to flow directly back to the refrigeration equipmentthrough the ceiling.
① Multiple sections of aluminum alloy profiles are pre assembled into modular compo nents, and a modular assembly mode is dopted on site; No welding in anyform is allowed on site.
② The frame is made of 6063-T5 aluminum alloy (natural anodized), and the cross-section meets national standards. The surrounding baffles within the framework are made of double-layer hollowfire-resistant sunlight panels, with a middle air layer and a heattransfer coefficient of<4.5W/ (m2 x K).
③ The passage door can be selected as a double sliding door or a double sliding door accor ding to the style requirements, and can be equipped with various forms such as door closers and access control.